The mainframe of Weclearmed® Nurse Call System is applied in the nurse station.
The mainframe is made up of a control section, a patient list and a telephone.
The control section of Weclearmed® Nurse Call System mainframe is equipped with display and setting functions.
The patient list of Weclearmed® Nurse Call System mainframe composed of patient card boxes is shown on the mainframe panel of the nurse station.
The telephone of Weclearmed® Nurse Call System mainframe that directly connected to the mainframe is placed on the desk of the nurse station, and the telephone is used for the two-way intercom between the nurse station and the patient beds.
For the Extension Weclearmed® Nurse Call System, there are more than 10 models of extensions nurse call system to choose, with the same wiring and settings.
☑ Calls are made between the patients’ beds and the nurse station.
☑ Calls are made step by step in a pre-set sequence of emergencies.
☑ Call records can be checked at the nurse station.
☑ Repeated broadcast of the bed number while calling.
☑ Easy to install and maintain with wire modules and two-wire system.
☑ The interface of the system with comprehensive functions is easy to operate.
☑ Exquisite appearance, a variety of models for users to choose.
Technical Parameters of the Mainframe |
|
Power |
AC220v+10%,50Hz+1Hz |
Temperature |
-10℃~45℃ |
Relative humidity |
≤85% |
Operating mode |
continuous |
Static power |
≤12w |
Full load power |
≤75w |
Bus voltage |
27±1V |
Maximum options for patient cards |
60nos,90nos, 120nos |
Maximum communication distance |
200 metres |
Maximum beds of extension nurse call |
120 beds |
Technical Specification of Extension Nurse Call |
|||
Power Source |
AC100V~240V,50~60Hz |
||
Working Circumstances |
Temperature:-10~45℃,Relative Humidity:≤85% |
||
Working Mode |
Continuous |
||
Static Power |
≤12W |
||
Full Load Power |
≤75W |
||
Bus Voltage |
24V+1V |
||
Bed Extension Capacity |
60nos,90nos,120nos |
||
Max.Transmission Distance |
200 Metre |
||
Bed Extension Specification |
|||
Model |
Installation Type |
Dimension(L*W*H) |
Hole size (L*W) |
CLEARMD-817 |
Wall-mounted |
126mm*78mm*16mm |
\ |
CLEARMD-967 |
Wall-mounted |
129mm*78mm*15mm |
\ |
CLEARMD-816 |
Flush-mounted |
125mm*77mm*20mm |
117mm*67mm |
Flush-mounted |
123mm*76mm*17mm |
104mm*65mm |
|
CLEARMD-815 |
Flush-mounted |
124mm*77mm*17.5mm |
104mm*65mm |
CLEARMD-965 |
Flush-mounted |
125mm*82mm*21mm |
91mm*67mm |
CLEARMD-868 |
Flush-mounted |
130mm*83mm*18mm |
104mm*65mm |
CLEARMD-968 |
Two types |
86mm*86mm*20mm |
69mm*50mm |
CLEARMD-811 |
Two types |
86mm*86mm*35mm |
70mm*70mm |
CLEARMD-986 |
Flush-mounted |
129mm*79mm*14mm |
70mm*70mm |